trats/trats2: exynos_power_init: return 0 if no battery detected.

Generic board support is now enabled for Exynos 4, and if any
init function returns an error then the init process is stopped.

This makes a boot issue on the Trats and Trats2 devices. If the device
is supplied by USB cable or an external power supply then it can't boot
because function exynos_power_init returns an error. Now this function
returns 0 if battery is not connected.

Signed-off-by: Przemyslaw Marczak <p.marczak@samsung.com>
Cc: Lukasz Majewski <l.majewski@samsung.com>
Cc: Piotr Wilczek <p.wilczek@samsung.com>
Cc: Minkyu Kang <mk7.kang@samsung.com>
Signed-off-by: Minkyu Kang <mk7.kang@samsung.com>
master
Przemyslaw Marczak 10 years ago committed by Minkyu Kang
parent f8caed3131
commit 4a1883651f
  1. 2
      board/samsung/trats/trats.c
  2. 2
      board/samsung/trats2/trats2.c

@ -332,7 +332,7 @@ int exynos_power_init(void)
if (!p_chrg->chrg->chrg_bat_present(p_chrg)) {
puts("No battery detected\n");
return -1;
return 0;
}
p_fg->fg->fg_battery_check(p_fg, p_bat);

@ -214,7 +214,7 @@ int exynos_power_init(void)
if (!p_chrg->chrg->chrg_bat_present(p_chrg)) {
puts("No battery detected\n");
return -1;
return 0;
}
p_fg->fg->fg_battery_check(p_fg, p_bat);

Loading…
Cancel
Save