Patch adds modification to shared omap5 abb_setup() function, and
proper registers definitions needed for ABB setup sequence. ABB is
initialized for MPU voltage domain at OPP_NOM.
Signed-off-by: Nishanth Menon <nm@ti.com>
Reviewed-by: Tom Rini <trini@ti.com>
Adaptive Body Biasing (ABB) modulates transistor bias voltages
dynamically in order to optimize switching speed versus leakage.
Adaptive Body-Bias ldos are present for some voltage domains
starting with OMAP3630. There are three modes of operation:
* Bypass - the default, it just follows the vdd voltage
* Foward Body-Bias - applies voltage bias to increase transistor
performance at the cost of power. Used to operate safely at high
OPPs.
* Reverse Body-Bias - applies voltage bias to decrease leakage and
save power. Used to save power at lower OPPs.
Signed-off-by: Andrii Tseglytskyi <andrii.tseglytskyi@ti.com>
Acked-by: Nishanth Menon <nm@ti.com>