The execution flow is currently like this for aldo_num == 1 or 2:
int axp_set_aldo(int aldo_num, unsigned int mvolt)
{
...
if (mvolt == 0)
return pmic_bus_clrbits(AXP809_OUTPUT_CTRL1,
AXP809_OUTPUT_CTRL1_ALDO1_EN << (aldo_num - 1));
...
return pmic_bus_clrbits(AXP809_OUTPUT_CTRL1,
AXP809_OUTPUT_CTRL1_ALDO1_EN << (aldo_num - 1));
}
I.e. aldo1 and aldo2 will always be disabled. This patch fixes it by
setting (rather than clearing) the enable bit when mvolt != 0.
Signed-off-by: Rask Ingemann Lambertsen <rask@formelder.dk>
Fixes: 795857df41
("sunxi: power: add AXP809 support")