@ -627,13 +627,8 @@ void board_init_f (ulong bootflag) |
|
|
|
|
*/ |
|
|
|
|
void board_init_r (gd_t *id, ulong dest_addr) |
|
|
|
|
{ |
|
|
|
|
cmd_tbl_t *cmdtp; |
|
|
|
|
char *s; |
|
|
|
|
bd_t *bd; |
|
|
|
|
extern void malloc_bin_reloc (void); |
|
|
|
|
#ifndef CONFIG_ENV_IS_NOWHERE |
|
|
|
|
extern char * env_name_spec; |
|
|
|
|
#endif |
|
|
|
|
ulong malloc_start; |
|
|
|
|
|
|
|
|
|
#ifndef CONFIG_SYS_NO_FLASH |
|
|
|
@ -646,18 +641,7 @@ void board_init_r (gd_t *id, ulong dest_addr) |
|
|
|
|
gd->flags |= GD_FLG_RELOC; /* tell others: relocation done */ |
|
|
|
|
|
|
|
|
|
/* The Malloc area is immediately below the monitor copy in DRAM */ |
|
|
|
|
#if defined(CONFIG_RELOC_FIXUP_WORKS) |
|
|
|
|
gd->reloc_off = 0; |
|
|
|
|
malloc_start = dest_addr - TOTAL_MALLOC_LEN; |
|
|
|
|
#else |
|
|
|
|
gd->reloc_off = dest_addr - CONFIG_SYS_MONITOR_BASE; |
|
|
|
|
malloc_start = CONFIG_SYS_MONITOR_BASE + gd->reloc_off - |
|
|
|
|
TOTAL_MALLOC_LEN; |
|
|
|
|
#endif |
|
|
|
|
|
|
|
|
|
#if defined(CONFIG_MPC85xx) || defined(CONFIG_MPC86xx) |
|
|
|
|
gd->cpu += gd->reloc_off; |
|
|
|
|
#endif |
|
|
|
|
|
|
|
|
|
#ifdef CONFIG_SERIAL_MULTI |
|
|
|
|
serial_initialize(); |
|
|
|
@ -682,38 +666,6 @@ void board_init_r (gd_t *id, ulong dest_addr) |
|
|
|
|
|
|
|
|
|
monitor_flash_len = (ulong)&__init_end - dest_addr; |
|
|
|
|
|
|
|
|
|
/*
|
|
|
|
|
* We have to relocate the command table manually |
|
|
|
|
*/ |
|
|
|
|
for (cmdtp = &__u_boot_cmd_start; cmdtp != &__u_boot_cmd_end; cmdtp++) { |
|
|
|
|
ulong addr; |
|
|
|
|
addr = (ulong) (cmdtp->cmd) + gd->reloc_off; |
|
|
|
|
#if 0 |
|
|
|
|
printf ("Command \"%s\": 0x%08lx => 0x%08lx\n", |
|
|
|
|
cmdtp->name, (ulong) (cmdtp->cmd), addr); |
|
|
|
|
#endif |
|
|
|
|
cmdtp->cmd = |
|
|
|
|
(int (*)(struct cmd_tbl_s *, int, int, char *[]))addr; |
|
|
|
|
|
|
|
|
|
addr = (ulong)(cmdtp->name) + gd->reloc_off; |
|
|
|
|
cmdtp->name = (char *)addr; |
|
|
|
|
|
|
|
|
|
if (cmdtp->usage) { |
|
|
|
|
addr = (ulong)(cmdtp->usage) + gd->reloc_off; |
|
|
|
|
cmdtp->usage = (char *)addr; |
|
|
|
|
} |
|
|
|
|
#ifdef CONFIG_SYS_LONGHELP |
|
|
|
|
if (cmdtp->help) { |
|
|
|
|
addr = (ulong)(cmdtp->help) + gd->reloc_off; |
|
|
|
|
cmdtp->help = (char *)addr; |
|
|
|
|
} |
|
|
|
|
#endif |
|
|
|
|
} |
|
|
|
|
/* there are some other pointer constants we must deal with */ |
|
|
|
|
#ifndef CONFIG_ENV_IS_NOWHERE |
|
|
|
|
env_name_spec += gd->reloc_off; |
|
|
|
|
#endif |
|
|
|
|
|
|
|
|
|
WATCHDOG_RESET (); |
|
|
|
|
|
|
|
|
|
#ifdef CONFIG_LOGBUFFER |
|
|
|
@ -721,7 +673,6 @@ void board_init_r (gd_t *id, ulong dest_addr) |
|
|
|
|
#endif |
|
|
|
|
#ifdef CONFIG_POST |
|
|
|
|
post_output_backlog (); |
|
|
|
|
post_reloc (); |
|
|
|
|
#endif |
|
|
|
|
|
|
|
|
|
WATCHDOG_RESET(); |
|
|
|
@ -752,7 +703,6 @@ void board_init_r (gd_t *id, ulong dest_addr) |
|
|
|
|
asm ("sync ; isync"); |
|
|
|
|
|
|
|
|
|
mem_malloc_init (malloc_start, TOTAL_MALLOC_LEN); |
|
|
|
|
malloc_bin_reloc (); |
|
|
|
|
|
|
|
|
|
#if !defined(CONFIG_SYS_NO_FLASH) |
|
|
|
|
puts ("FLASH: "); |
|
|
|
|