Low Frequency Periodic Singaling (LFPS) Peak-to-Peak Differential Output Voltage Test Compliance fails using default transmitter settings Change config of transmitter signal swings by setting register PCSTXSWINGFULL to 0x47 to pass compliance tests. Signed-off-by: Sriram Dash <sriram.dash@nxp.com> Signed-off-by: Rajesh Bhagat <rajesh.bhagat@nxp.com> Signed-off-by: Suresh Gupta <suresh.gupta@nxp.com> Signed-off-by: Ran Wang <ran.wang_1@nxp.com> [YS: Reordered Kconfig options] Reviewed-by: York Sun <york.sun@nxp.com>master