"reset.c" and "cpu.c" have no architecture-specific code at all.
Others are applicable to either ARC CPU.
This change is a preparation to submission of ARCv2 architecture port.
Even though ARCv1 and ARCv2 ISAs are not binary compatible most of
built-in modules still have the same programming model - AUX registers
are mapped in the same addresses and hold the same data (new featues
extend existing ones).
So only low-level assembly code (start-up, interrupt handlers) is left
as CPU(actually ISA)-specific. This significantyl simplifies maintenance
of multiple CPUs/ISAs.
Signed-off-by: Alexey Brodkin <abrodkin@synopsys.com>
Signed-off-by: Igor Guryanov <guryanov@synopsys.com>
To disable interrupts we need to reset corresponding flags in STATUS32
register. For this we need to OR flags for interrupts level1 and level2
and then AND with current value in STATUS32.
Before that implementation was incorrect.
Signed-off-by: Alexey Brodkin <abrodkin@synopsys.com>
Signed-off-by: Igor Guryanov <guryanov@synopsys.com>
Exception cause register (ECR) contains value that describes a reason
for exception that has happened. This helps a lot to figure-out what
went wrong.
Now we print this register contents when dumping registers.
Signed-off-by: Alexey Brodkin <abrodkin@synopsys.com>
Signed-off-by: Igor Guryanov <guryanov@synopsys.com>